AG-IIR003BProduct Name:Hospital Medical Infant IncubatorWhen need move baby incubator, pull or push it by the handle at the two side of incubatorPull front left handle of ...
When need move baby incubator, pull or push it by the handle at the two side of incubator
Pull front left handle of constant temp hood out and rotary, and then press operation window locking device, can open front door. When closed it, right locking device can self-lock, left handle should rotary and make it stuck locating slot located front door.
There are operating windows at hood’s front and back, so as two (or more than two) medical workers to go on with the baby through operation window. While opening the window, the medical worker only needs to press the lock organization with the finger, the window goalkeeper opened automatically.
There are circle operation window at the side, use for infusion or vent line. when use, first use one side of specified cloth cover put on the liner side of constant temp hood, the other side cover outer side (penetration the infusion or vent line, can not penetration also) ,then rotate the outer handle of cloth cover, make cloth cover ventage reduce to closed.
When upward open the constant hood, the Support locking plate will limit the height of uplift, and have support effect. When closed it, must press support locking plate downward, constant temp hood will closed after self-locking bolt break away from limit
Medical worker's hands feel comfortable while stretching into and operating in the window, play a sealed role after the window is shut off.
Specification:
1.Microprocessor based servo controlled temperature system
2.Air temperature,skin temperature,humidity,timer and heat power separately displayed by LED
3.Alarms functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
4.Silence/reset button for alarms
5.Integral timer to record therapy time
6.Humidity is adjustable continuously
7.>37°C temperature setting
8.A keypad lock prevent inadvertent changes the setting
9.Trough for pulling and pushing ,which is convenient to add water and wash
10.Fan with low noise and long life-span
11.Temperature deviation and over temperature could be amended in front panel directly
12.A second thermal cut-off function for more safety
13.Skin temperature sensor failure protect function avoid over temperature
14.The infant bed inclination angle is adjustable
15.six operating windows,two sides operating windows can be swiveled
16.Heater is electrically cut-out if air temperature inside incubator exceed 40°C
17.big storage cabinet
Standard configuration
Main body(including the transparent hood,control system,infant bed,water trough),
skin temperature sensor,I.V.pole, mattress, height adjustable ;cabinet, castors